Back to top

Medical Gas Pipeline System

Medical Gas Pipeline System
Medical Gas Pipeline System
Medical Gas Pipeline System
Medical Gas Pipeline System
Medical Gas Pipeline System
Medical Gas Pipeline System
Medical Gas Pipeline System
Medical Gas Pipeline System
Medical Gas Pipeline System
Medical Gas Pipeline System
Medical Gas Pipeline System
Medical Gas Pipeline System
Medical Gas Pipeline System
Medical Gas Pipeline System
Medical Gas Pipeline System
Medical Gas Pipeline System

Medical Gas Pipeline System Specification

  • Equipment Type
  • Hospital Pipeline Supply & Installation
  • Material
  • Other
  • Condition
  • New
  • Portable
  • No
  • Disposable
  • No
  • Wall Mounted
  • Yes
  • Waterproof
  • Yes
  • Sound Prompt
  • No
  • Operating Type
  • Semi-Automatic
  • Power Source
  • Electric
  • Dimension (L*W*H)
  • 80x115 Millimeter (mm)
  • Weight
  • 0.72 Kilograms (kg)
  • Color
  • Custom
  • Usage
  • Hospital Pipeline
  • Warranty
  • Yes
 

Medical Gas Pipeline System Trade Information

  • Minimum Order Quantity
  • 100 Meters
  • Supply Ability
  • 1000 Meters Per Month
  • Delivery Time
  • Days
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 13485 & CE Certified
 

About Medical Gas Pipeline System

1. Design and Planning

  • Pipeline Sizing: Designed to meet the specific gas flow requirements of the facility.
  • Material: Typically, copper pipes (Type L or K) are used for medical gas pipelines.
  • Compliance: Adheres to international standards like NFPA 99 (National Fire Protection Association), HTM 02-01, and other relevant ISO standards.
  • Layouts and Blueprints: Detailed design drawings for medical gas pipelines are prepared in advance, showing location, dimensions, and sizing.

2. Components for Installation

  • Medical Gas Outlets: Specific outlets per gas type (Oxygen, Nitrous Oxide, Medical Air, Vacuum, etc.).
    • MAP Company outlets typically feature color-coded and key-coded designs for safety and easy identification.
  • Zonel Valves: Enables isolation of specific zones or sections in emergencies.
    • Designed for easy access, usually installed at prominent, accessible points.
  • Alarm Systems: Monitors pipeline pressure and alerts for any irregularities.
  • Manifold Systems: Controls gas supply and ensures uninterrupted delivery.
  • Control Panels: Centralized control over multiple gases for ease of operation.
  • Pressure Regulators and Gauges: Ensures the gas is supplied at consistent, regulated pressure.

3. Installation Process

  • Piping: Pipes are brazed using high-quality filler metals to prevent leaks and corrosion.
  • Purging: The system is purged using Nitrogen to prevent contamination and oxidation during brazing.
  • Labeling: Gas lines are color-coded and labeled per gas type along their length.
  • Connections: Flanged, quick-connect, or threaded connections as per design.

4. Testing Procedures

  • Pressure Testing: Tests for leakages by pressurizing the system with an inert gas (often Nitrogen).
    • Pressure Levels: Typically 1.5 times the working pressure.
  • Leak Testing: Vacuum is applied to the system and checked for any pressure drop over a set period.
  • Purity Testing: Ensures that the pipeline is free from contaminants before first use.

5. Commissioning and Documentation

  • Flow and Pressure Verification: Confirm that gases flow at the required pressure and volume to all outlets.
  • System Documentation: Includes blueprints, certificates of compliance, inspection reports, and test results.
  • Staff Training: Instruct medical staff on the usage and emergency protocols associated with the gas pipeline system.

( MedicalAir Product ) would also typically include additional documentation likewarranty terms, maintenance schedules, and replacement part listings..

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Medical Gas Pipeline System Category

MGPS Work

MGPS Work

Price 800 INR / Meter

Minimum Order Quantity : 100

Power Source : Other

Wall Mounted : Yes

Operating Type : Manual

Usage : For Medical Gases

Oxygen Gas Supply Bed Head Panel Unit

Oxygen Gas Supply Bed Head Panel Unit

Price 900 INR / Foot

Minimum Order Quantity : 50 Feet

Power Source : Electric

Wall Mounted : Yes

Operating Type : SemiAutomatic

Usage : Hospital